Typical Properties of Double-side Rough Copper Foil
Classification | Unit | Requirement | Test Method | |||||
Nominal thickness | um | 6 | 8 | 9 | 10 | 12 | IPC-4562A | |
Area Weight | g/m² | 54±2 | 70-75 | 85-90 | 95-100 | 105-110 | IPC-TM-650 2.2.12.2 | |
Purity | % | ≥99.9 | IPC-TM-650 2.3.15 | |||||
Roughness | Shiny side (Ra) | սm | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | ≤0.5 | IPC-TM-650 2.3.17 |
Matte side(Rz) | um | ≤4.0 | ≤4.0 | ≤4.0 | ≤4.5 | ≤5.0 | ||
Tensile Strength | R.T.(23°C) | Mpa | ≥294 | ≥294 | ≥294 | ≥294 | ≥294 | IPC-TM-650 2.4.18 |
H.T.(180°C) | ≥147 | ≥147 | ≥147 | ≥147 | ≥147 | |||
Elongation | R.T.(23°C) | % | ≥2.5 | ≥2.5 | ≥2.5 | ≥2.5 | ≥2.5 | IPC-TM-650 2.4.18 |
H.T.(180°C) | ≥2.0 | ≥2.0 | ≥2.0 | ≥2.0 | 2.0 | |||
Pinholes & Porosity | Number | No | IPC-TM-650 2.1.2 | |||||
Anti-oxidization | R.T.(23°C) | 90 | ||||||
R.T.(160°C) | 15 |